MC-1200
Martel
Home
Multi-Function Calibrator |
|

The Martel MC-1200 Multi-Function
Calibrator provides a feature set unmatched in high accuracy, hand-held
calibrators in its price range. The MC-1200 Calibrator provides
the functions and accuracy associated with fixed-installation, laboratory
instruments, and has everything needed for virtually any calibration
task. Measure and source thermocouples, RTDs, current, voltage,
and frequency, and source pulse trains.
A communications port compatible with
Fluke® 700 Series, Mensor®, and Martel pressure modules
is provided, as is an isolated mA/V read-back circuit. Arrow keys,
direct numeric keypad entry, and three software-driven function
buttons, plus a large backlit, menu-driven graphics display combine
to provide a highly intuitive, simple yet powerful operator interface.
Built-in 250 Ohm resistor for Hart™
compatibility, compatibility with smart transmitters and PLCs, full
fuseless protection, and a serial communications port for full control
with ASCII commands, are just some of the additional features that
make the MC-1200 the single, most indispensable tool available for
virtually any calibration task. The MC-1200 is supplied in a tough,
rubber boot; a carrying case is also available as an option. |
|
COMMON FEATURES |
| Measure and source T/Cs (13 types),
RTDs (13 types), Ohms, current, voltage, frequency; source pulse
trains |
| Isolated mA/V
read-back circuit for complete transmitter calibration |
| Pressure module
communication port compatible with Fluke 700 Series, Mensor,
and Martel pressure modules |
| Built-in 24
V supply can drive 4 – 20 mA loops up to 1000 Ohms |
| Direct entry
of custom RTD coefficients (RO, A, B, C) |
| All source
modes can be programmed with dedicated setpoints to speed calibration
and linearity tests |
| Highest accuracy in class to 0.015%
of reading |
| Meets CE requirements and is designed
to IEC 1010 safety standard |
| Fluke, Mensor, and Martel
Pressure Modules |
| General
Specifications: |
|
Voltage Read and Source: |
| Source |
|
0.000 to 20.000 VDC |
| Read |
|
|
| |
Isolated |
0.000 to 30.000 VDC |
| |
Non-isolated |
0.000 to 20.000 VDC |
|
|
Thermocouple mV: |
Read and Source -10.000 to +75.000 mV
|
|
Current (mA): |
| Source |
|
0.000 to 24.000 mA |
| Read |
|
|
| |
Isolated |
0.000 to 24.000 mA |
| |
Non-isolated |
0.000 to 24.000 mA |
|
|
Frequency (1 to 20 V selectable
amplitude): |
| CPM Source and Read |
2.0 to 600.0 CPM |
| Hz Source and Read |
1.0 to 1000.0 Hz |
| kHz Source and Read |
1.0 to 10.00 kHz |
|
|
Pulse (Source only; 1 to 20V
selectable amplitude): |
| Pulses |
1 to 30,000.0 |
| |
2 CPM to 10 kHz |
|
|
Ohms: |
| Source |
5.0 to 4000 Ohms |
| Read |
0.00 to 4000.0 Ohms |
|
|
Thermocouple Read and Source: |
| J Thermocouple |
-200.0 to +1200.0 °C |
| K Thermocouple |
-200.0 to +1370.0 °C |
| T Thermocouple |
-200.0 to +400.0 °C |
| E Thermocouple |
-200.0 to +950.0 °C |
| R Thermocouple |
-20.0 to +1750.0 °C |
| S Thermocouple |
-20.0 to +1750.0 °C |
| B Thermocouple |
+600.0 to +1800.0 °C |
| C Thermocouple |
0 to +2316.0 °C |
| XK Thermocouple |
-200.0 to +800.0 °C |
| BP Thermocouple |
0 to +2500.0 °C |
| L Thermocouple |
-200.0 to +900.0 °C |
| U Thermocouple |
-200.0 to +400.0 °C |
| N Thermocouple |
-200.0 to +1300.0 °C |
|
|
RTD Read and Source: |
| Ni120 (672) |
-80.0 to +260.0 °C |
| Pt100 (385) |
-200.0 to +800.0 °C |
| Pt100 (3926) |
-200.0 to +630.0 °C |
| Pt100 (3916) |
-200.0 to +630.0 °C |
| Pt200 (385) |
-200.0 to +630.0 °C |
| Pt500 (385) |
-200.0 to +630.0 °C |
| Pt1000 (385) |
-200.0 to +630.0 °C |
| Cu10 |
-100.0 to +260.0 °C |
| YSI400 |
+15.00 to +50.00 °C |
| Cu50 |
-180 to +200 °C |
| Cu100 |
-180 to +200 °C |
| Pt385-10 |
-200 to +800.0 °C |
| Pt385-50 |
-200 to +800.0 °C |
|
|
Environmental: |
| Operating Temperature |
-10°C to +50°C |
| Storage Temperature |
-20°C to +70°C |
| Stability |
±0.005% of reading/°C outside
of 23 °C ±5°C |
| Power Requirements |
6 VDC; Batteries 4x AA; alkaline or
optional rechargeable |
| Physical (includes rubber boot) |
Dimensions 8.7"H x 4.2"W
x 2.3"D (220.9 x 106.6 x 58.4 mm)
Weight 30.5 ounces (863 grams) |
| Accessories Included |
Test leads, 4-AA alkaline batteries,
NIST Certificate, and instruction manual |
| Optional Accessories |
Carrying Case, Model CC572 |
|
|
Accuracy: |
|
Voltage2 |
±0.015% of reading, ±2
mV |
| Thermocouple |
|
mV ±0.02% of reading, ±10
µV |
| Thermocouple Errors (in °C; add 0.2 for Cold Junction
Compensation error) |
RTD Read and Source |
| Type J |
0.2 °C |
Ni120 (672) |
0.2 °C |
| Type K |
0.3°C |
Pt100 (385) |
0.2 °C |
| Type T |
0.2 °C |
Pt100 (3926) |
0.2 °C |
| Type E |
0.2 °C |
Pt100 (3916) |
0.2 °C |
| Type R |
1.2 °C |
Pt200 (385) |
0.8°C |
| Type S |
1.2 °C |
Pt500 (385) |
0.4°C |
| Type B |
1.2 °C |
Pt1000 (385) |
0.2 °C |
| Type C |
0.6°C |
Cu10 |
1.4°C |
| Type XK |
0.2 °C |
YSI400 |
0.1°C |
| Type BP |
0.9°C |
Cu50 |
0.4°C |
| Type L |
0.2 °C |
CU100 |
0.3°C |
| Type U |
0.25 °C |
Pt385-10 |
1.4°C |
| Type N |
0.4°C |
Pt385-50 |
0.4°C |
|
|
RTD IEX-range: |
| |
Read |
Source |
| Current (mA) |
±0.015% of reading,
±2 µA |
±0.015% of reading,
±2 µA |
| CPM |
±0.05% of reading |
±1 LSD ±0.05%
of reading |
| Hz |
±0.05% of reading |
±1 LSD ±0.05%
of reading |
| kHz |
±0.05% of reading |
±1 LSD ±0.125%
of reading |
| Ohms |
| 400 Ohm Range |
±0.025% of reading,
±0.05 Ω |
±0.025% of reading,
±0.05 Ω |
| 4000 Ohm Range |
±0.025% of reading,
±0.5 Ω |
±0.025% of reading,
±0.5 |
|
 |
The MC-1200 is compatible with Fluke®,
Mensor®, and Martel pressure modules. Both Fluke and Martel
pressure modules are available from Martel Electronics. Please
refer to the separate Pressure Modules data sheet for ranges
and model numbers. (Pressure modules require accessory Model
700MA Module Adapter.) |
|
|
|