Penetration Thermocouple Probes
Barnant (Oakton Home)
| ORDERING INFORMATION |
|
Small Diameter
Thermocouple Penetration Probes
4"L. Include 5 - ft coiled cable. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
D |
93601-02 |
J |
-310 to 1300 (-190 to
704) |
Junction: grounded
Time constant:2 sec
Response Time: 10 sec
316 SS sheath; Miniconnector
Glass - filled polypropylene handle. |
|
93601-04 |
K |
-418 to 1500 (-250 to
816) |
|
93601-06 |
T |
-418 to 650 (-250 to 343) |
 |
| Penetration Probes |
| 4"L. Include 5 - ft
coiled cable. Ideal for soft and semisoft materials. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
B |
8517-65 |
J |
-310 to 1400 (-190 to
760) |
Junction: grounded
Time constant:5 sec (liquids)
Response Time: 25 sec (liquids)
316 SS sheath; Miniconnector
Glass - filled polypropylene handle. |
|
8516-65 |
K |
-418 to 1650 (-250 to
899) |
|
8500-65 |
T |
-418 to 752 (-250 to 400) |
|
8512-65 |
E |
-418 to 1600 (-250 to
871) |
 |
| Heavy-duty Thermocouple Penetration Probes |
| 12"L - extra length for
large samples. Ideal for use in soft grounds and semi frozen
materials. Include 5 -ft coiled cable. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
H |
93601-22 |
J |
-310 to 1400 (-190 to
760) |
Junction: grounded
Time constant: 30 sec
Response Time: 150 sec
316 SS sheath
Miniconnector |
|
93601-24 |
K |
-418 to 1652 (-250 to
900) |
|
93601-26 |
T |
-418 to 700 (-250 to 371) |
 |
| Heavy-Duty Thermocouple Penetration Probes With T-Style,
Stainless Steel Handles |
| 10"L. Rugged handle is
ideal for use with all types of aggregates in the construction
industry. Include 4 - ft SS armored cable for added
durability. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
J |
93601-82 |
J |
-310 to 1400 (-190 to
760) |
Junction: grounded
Time constant: 10 sec
Response Time: 50 sec
316 SS sheath
Miniconnector |
|
93601-84 |
K |
-418 to 1652 (-250 to
900) |
|
93601-86 |
T |
-418 to 550 (-250 to 287) |
 |
| Heavy-Duty Stainless Steel Thermocouple Penetration
Probes |
| 6"L. Use for soft or
semisoft materials such as semi-frozen meats, liquids, or
plastics. Sharp tip penetrates 6". Include 5 - ft coiled
cable. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
K |
8517-67 |
J |
-310 to 1400 (-190 to
760) |
Junction: grounded
Time constant: 6 sec
Response Time: 30 sec
316 SS sheath
Miniconnector |
|
8516-67 |
K |
-418 to 1652 (-250 to
900) |
|
8500-67 |
T |
-418 to 550 (-250 to 287) |
 |
| Food - service thermocouple probes with hypodermic tip. |
| 4"L. Include 4 - ft
straight armored cable. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
C |
93607-20 |
J |
-310 to 700 (-190 to 371)
|
Junction: grounded
Time constant: 2 sec
Response Time: 10 sec
316 SS sheath
Miniconnector; 316 SS handle |
|
93607-22 |
K |
-418 to 700 (-250 to 371) |
|
93607-24 |
T |
-418 to 700 (-250 to 371) |
| Hypodermic thermocouple probes |
| 4"L. Include 4 - ft
straight PVC cable and bendable sheath. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
E |
8116-65 |
J |
-310 to 700 (-190 to 371)
|
Junction: grounded
Time constant: 2 sec
Response Time: 10 sec
316 SS sheath
Miniconnector; 316 SS handle |
|
8117-65 |
K |
-418 to 700 (-250 to 371) |
|
8113-65 |
T |
-418 to 700 (-250 to 371) |
| Extra - long heavy - duty thermocouple probes |
| 24"L - extra length for
long samples. Ideal for use in soft ground and semi frozen
materials. Include 5 - ft coiled cable. |
|
Key |
Cat. no. |
Type |
Temperature
range in °F(°C) |
Features |
|
I |
93601-42 |
J |
-310 to 1400 (-190 to
760) |
Junction: grounded
Time constant: 10 sec
Response Time: 50 sec
316 SS sheath
Miniconnector |
|
93601-44 |
K |
-418 to 1652 (-250 to
900) |
|
93601-46 |
T |
-418 to 550 (-250 to 287) |
|
|
|