Low-Cost Thermocouple Probes
Barnant (Oakton Home)
Choose these
TC probes for economy. Each thermocouple probe has a 304 stainless steel sheath, 11/4" long x 3/4" diameter nylon handle (except surface probes) 3-ft color-coded PVC cable, and color-coded mini-connector. Choose probes with 20 gauge straight solid core wire cable (holds shape when bent); or coiled cable.Each probe has a characteristic time constant (response time). Five time constants are needed to reach 99% of final reading. See descriptions below for the time constant of each type probe.
| ORDERING INFORMATION |
|
General-Purpose Probes
Grounded junction. Time Constant: 6 sec
|
| Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8439-60 |
J |
-310 to 1400 (-190 to 760) |
Junction: grounded Time constant: 6 Sec
(liquids) Response Time: 30 sec (liquids) 304 SS sheath;
Mini-connector; Glass - filled polypropylene handle. |
|
8439-62 |
K |
-418 to 1650 (-250 to 899) |
|
8439-64 |
T |
-418 to 725 (-250 to 400) |
| Teflon ®¨-Coated Probes |
4.5"L; for use with corrosive liquids. Include 5 - ft coiled cable.
|
| Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8441-10 |
J |
-310 to 302 (-190 to 150) |
Junction: grounded Time constant: 11
Sec (liquids) Response Time: 55 sec (liquids) 304 SS sheath;
Mini-connector; Glass - filled polypropylene handle. |
|
8441-12 |
k |
-418 to 302 (-250 to 150) |
|
8441-14 |
T |
-418 to 302 (-250 to 150) |
| Penetration Probes |
Sharp pointed tip. grounded junction. Time constant: 5 seconds (liquids).
|
|
Key |
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
A |
8439-80 |
J |
-310 to 1400 (-190 to 760) |
Junction: grounded Time constant: 5 Sec
(liquids) Response Time: 25 sec (liquids) 304 SS sheath;
Mini-connector; Glass - filled polypropylene
handle. |
|
8439-82 |
K |
-418 to 1650 (-250 to 899) |
|
8439-84 |
T |
-418 to 752 (-250 to 400) |
| Surface Probes |
4.75"L. Exposed junction is isolated from aluminum housing with ceramic support. Include 5 -ft coiled cable.
|
| Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8439-70 |
J |
-310 to 1200 (-190 to 649) |
Junction: exposed; isolated Time constant: 6 Sec Response Time: 30 sec
Aluminum housing; Mini-connector. |
|
8439-72 |
K |
-418 to 1200 (-250 to 649) |
|
8439-74 |
T |
-418 to 700 (-250 to 371) |
| Air/Gas Probes |
Exposed junction is isolated from sheath; protected by 304 SS wire coiled around it. Time constant: 45 seconds (5m/second airflow).
|
| Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8439-90 |
J |
-310 to 572 (-190 to 300) |
Junction: exposed; isolated Time constant: 45 s at 5 m/s airflow Response Time: 225 s at 5 m/s airflow 304 SS sheath and SS wire coil
Mini-connector; nylon handle |
|
8439-92 |
K |
-418 to 572 (-250 to 300) |
|
8439-94 |
T |
-418 to 572 (-250 to 300) |
|