We Take Test

Equipment Trade-Ins!

 

 

INDEX

 

by VENDOR

 

by PRODUCT

 

 
     
 

Printable

LINE-CARD

 
     
 

Technical References

 
 

TEMPERATURE CONVERTER

 
 

PRESSURE CONVERTER

 
 

NEMA RATINGS

 

 

INSTRUMENTS BY INDUSTRY

CHEMICAL
FOOD
HOSPITALS
MANUFACTURING
PHARMACEUTICAL
PIPELINES
POWER
REFINING
WATER
 
Related Products of Interest
Dry Block Temperature Calibrators Temperature Calibrators Thermocouples and RTDs Bi-Metal Thermometers Long-Life Thermometers
 
Integral Handle Type J, K, T, and E Thermocouple Probes                                                                           Barnant (Oakton Home)
  • Durable 51/2" long glass-filled nylon handles
     
  • Choose 5-ft. coiled cables with thermocouple miniconnectors or 10-ft straight cables with stripped ends

Visit General Purpose Thermocouple Probes to choose integral-handle thermocouple probes with 5-ft. coiled cables or 10-ft. straight cables (some probes are available with coiled cable only). Coiled cables have mini-connector plugs for quick attachments. Straight cables have stripped-end probe leads, which attach to mini- or standard connectors or screw-terminal instruments. Use spade lugs for good connections when attaching straight cable probe leads to screw terminals. Use the spade lug that matches the metal wire in your probe lead.

Each probe is equipped with a durable 5-1/2" long glass-filled polypropylene handle. Strain relief spring on handle protects the cable connection against damage due to flexing and tugging. Cables feature PVC/PVC insulation and are ANSI color-coded for easy identification: Type J cables are black, Type K are yellow, Type T are blue, and Type E are purple.

Each probe has a characteristic time constant (response time). Five time constants are needed to reach 99% of final reading. For example, a probe with a time constant of 5 seconds reaches its final reading in about 25 seconds. See descriptions for the time constant of each probe.

 

ORDERING INFORMATION

 

Standard Probes
4.5"L; for use with liquids, gases, and semi-solids. Include standard handle and 5-ft coiled cable.
Cat no Type Temperature Range
in °F(°C)
Features
8517-55 J -310 to 1400 (-190 to 760) Junction: grounded
Time Constant:3 sec (liquids)
Response Time:15 sec (liquids)
316 SS sheath; Miniconnector;
Glass-filled polypropylene handle.
8516-55 K -418 to 1650 (-250 to 899)
8500-55 T -418 to 752 (-250 to 400)
8512-55 E -418 to 1600(-250 to 871)

 

To Place an Order, or to Receive any Additional Information, Please e-mail:  process@bcgroupintl.com, call (314) 638-3800 or fax (314) 638-3200