General Purpose Thermocouple Probes
Barnant (Oakton Home)
| ORDERING INFORMATION |
|
Small Diameter
Thermocouple Probes
4"L; for use with liquids, gases and semisolids. Include standard
handle and 5 - ft coiled cable.
|
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8505-55 |
J |
-310
to 1300 (-190 to 704) |
Junction: grounded
Time constant: 2 Sec
Response Time: 10 sec
316 SS sheath; Mini-connector;
Glass - filled polypropylene handle. |
|
8505-56 |
K |
-418
to 1500 (-250 to 816) |
|
8505-57 |
T |
-418
to 650 (-250 to 343) |
 |
 |
| Teflon®-Coated
Thermocouple Probes |
| 10"L;
for use with corrosive chemicals and strong acids. Include
standard handle and 5 - ft coiled cable. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
93812-00 |
J |
-310
to 500 (-190 to 260) |
Junction: grounded
Time constant: 11 Sec
Response Time: 55 sec
316 SS sheath; Mini-connector;
Glass - filled polypropylene handle. |
|
93812-02 |
K |
-418
to 500 (-250 to 260) |
|
93812-04 |
T |
-418
to 500 (-250 to 260) |
 |
| Small - diameter
thermocouple probes |
| 8"L.
Ideal for checking food temperatures. Include 5 - ft coiled cable. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8505-61 |
J |
-310
to 1300 (-190 to 704) |
Junction: grounded
Time constant: 2 Sec
Response Time: 10 sec
316 SS sheath;
Mini-connector; SS handle. |
|
8505-62 |
K |
-418
to 1500 (-250 to 816) |
|
8505-63 |
T |
-418
to 650 (-250 to 343) |
| All stainless steel
TC probes |
| 8"L;
for added durability - ideal for food processing applications.
Include 4.5" L SS handle and 4 - ft SS armored cable. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
93600-02 |
J |
-310
to 1400 (-190 to 760) |
Junction: grounded
Time constant: 6 Sec
Response Time: 30 sec
316 SS sheath;
Mini-connector; SS handle. |
|
93600-22 |
K |
-418
to 1650 (-250 to 899) |
|
93600-42 |
T |
-418
to 752 (-250 to 400) |
| Extra - long stainless
steel TC probes |
| 10"L.
Use with liquids, gases and semisolids. Include standard handle
and 5 - ft coiled cable. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
93756-00 |
J |
-310
to 1400 (-190 to 760) |
Junction: grounded
Time constant: 3 Sec (liquids)
Response Time: 15 sec (liquids)
316 SS sheath; Mini-connector
Glass - filled polypropylene handle. |
|
93756-20 |
K |
-418
to 1650 (-250 to 899) |
|
93756-40 |
T |
-418
to 752 (-250 to 400) |
| Extra - long stainless
steel thermocouple probes with ungrounded junction |
| 10"L.
Use in electrically noisy environments. Include standard handle
and 5 - ft coiled cable. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
93758-00 |
J |
-310
to 1400 (-190 to 760) |
Junction: ungrounded
Time constant: 5 Sec
Response Time: 25 sec
316 SS sheath; Mini-connector
Glass - filled polypropylene handle. |
|
93758-02 |
K |
-418
to 1650 (-250 to 899) |
|
93758-04 |
T |
-418
to 752 (-250 to 400) |
|
93758-06 |
E |
-200
to 1600 (-129 to 871) |
| Fast - response
microprobe with 90° - angle tip |
|
4"L.
Include 5 - ft straight PVC - insulated cable.. |
|
Cat. no. |
Type |
Temperature range in °F(°C) |
Features |
|
8506-95 |
T |
-418
to 752 (-250 to 400) |
Junction: grounded
Time constant: 0.15 Sec
Response Time: 0.75 sec
304 SS sheath;
Mini-connector; PVC handle. |
|
|
8439-92 |
K |
-418 to 572 (-250 to 300) |
|
8439-94 |
T |
-418 to 572 (-250 to 300) |
|
|